Fluorosilicone
NUSIL™ MEDICAL
CF1-3510
Engineering / electronics / solvent resistant
Shore A20
Viscosity70000 cP
Tensile180 psi
Step 1 · Select Order Type
| Property | Typical Value | Unit | Reference |
|---|---|---|---|
| Work Time | 15 min | — | — |
| Specific Gravity | 1.12 | — | — |
| Durometer, Type A | 30 | — | — |
| Tensile Strength | 1175 psi / 8.1 Mpa | — | — |
| Elongation | 550% | — | — |
| Dielectric Strength | 900 volts/mil / 35.4 kV/mm | — | — |
Structured TDS screening summary only — not a purchase specification. Request the official current TDS PDF from BIO Corporation prior to design freeze.