Materials & Products
CV-2961
NuSil™ medical-grade silicone · supplied in China by BIO, an authorized NuSil™ Channel Partner
Product identification
Product identification
Use the complete product code when requesting documents, samples or a quotation.
- Full product code
CV-2961- Matching reference
- CV-2961 Product Profile / TDSDocument date 2018-12-12 · Revision B
Technical data
Typical properties and test methods
Request the current document for any missing data. Use only data for this product code.
Typical data from the reference TDS
CV-2961 Product Profile / TDS · Document date 2018-12-12 · Revision B
Values are shown in the document's original units. They are Typical data, not purchasing specifications. Values from different methods or conditions are not directly equivalent.
| Property | Typical value | Test method |
|---|---|---|
| Appearance, Part A | White | ASTM D2090 |
| Viscosity, Part A | 300,000 cP / 300,000 mPas | ASTM D1084, D2196 |
| Work Time | 2 hours | Not stated in this document |
| Specific Gravity | 1.38 | ASTM D792 |
| Durometer, Type A | 75 | ASTMD2240 |
| Tensile Strength | 275 psi / 1.9 MPa | ASTM D412 |
| Elongation | 40% | ASTM D412 |
| Lap Shear Strength (primed w/ CF1-135) | 150 psi / 1.0 MPa | ASTM D1002 |
Documents & lot records
Technical and lot documents
Request the current product documents and any lot-specific records required for your project.
- Product Profile / TDS referenceThe date identifies the reference used on this page; it does not establish the current revision, supply or a regulatory conclusion.CV-2961 Product Profile / TDS · Document date 2018-12-12 · Revision B
- Lot documentsRequest a CoA or other lot documents for your product code and lot.Available records depend on the product and lot
Using product information
Selection and validation
- Typical data supports technical discussion; it is not a purchasing specification.
- Material-level information is not finished-device approval. Suitability depends on the exact code, contact conditions and final device validation.
- Lot documents apply to a specific production lot. Confirm current documents before design or acceptance.
- NuSil™ and Avantor® are trademarks of their respective owners. BIO is not the manufacturer.
Discuss your application
Submit CV-2961 and application details
Tell BIO about the component, contact conditions, process, expected volume and documents you need. Request application support, samples or a quotation.