NuSil™ medical-grade silicone · supplied in China by BIO, an authorized NuSil™ Channel Partner

Product identification

Product identification

Use the complete product code when requesting documents, samples or a quotation.

Full product code
CV2-2289-1
Matching reference
CV2-2289-1 Product Profile / TDSDocument date 2022 · Revision C

Technical data

Typical properties and test methods

Request the current document for any missing data. Use only data for this product code.

Typical data from the reference TDS

CV2-2289-1 Product Profile / TDS · Document date 2022 · Revision C

Values are shown in the document's original units. They are Typical data, not purchasing specifications. Values from different methods or conditions are not directly equivalent.

PropertyTypical valueTest method
Appearance, Part AWhiteASTM D2090
Appearance, Part BTranslucentASTM D2090
Viscosity, Part A14,000 cP / 14,000 mPasASTM D1084, D2196
Viscosity, Part B10,500 cP / 10,500 mPasASTM D1084, D2196
Tack-Free Time10 hoursASTM C679
Durometer, Type A30ASTM D2240
Tensile Strength450 psi / 3.1 MPaASTM D412
Elongation200%ASTM D412
Lap Shear Strength (primed w/ CF1-135)200 psi / 1.4 MPaASTM D1002
Collected Volatile Condensable Material (CVCM)0.07%ASTM E595
Total Mass Loss (TML)0.31%ASTM E595

Documents & lot records

Technical and lot documents

Request the current product documents and any lot-specific records required for your project.

  • Product Profile / TDS referenceThe date identifies the reference used on this page; it does not establish the current revision, supply or a regulatory conclusion.CV2-2289-1 Product Profile / TDS · Document date 2022 · Revision C
  • Lot documentsRequest a CoA or other lot documents for your product code and lot.Available records depend on the product and lot

Request documents for this code

Using product information

Selection and validation

  • Typical data supports technical discussion; it is not a purchasing specification.
  • Material-level information is not finished-device approval. Suitability depends on the exact code, contact conditions and final device validation.
  • Lot documents apply to a specific production lot. Confirm current documents before design or acceptance.
  • NuSil™ and Avantor® are trademarks of their respective owners. BIO is not the manufacturer.

Discuss your application

Submit CV2-2289-1 and application details

Tell BIO about the component, contact conditions, process, expected volume and documents you need. Request application support, samples or a quotation.