Skip to main content

Materials & Products

CV2-2946

NuSil™ medical-grade silicone · supplied in China by BIO, an authorized NuSil™ Channel Partner

Product identification

Product identification

Use the complete product code when requesting documents, samples or a quotation.

Full product code
CV2-2946
Matching reference
CV2-2946 Product Profile / TDSDocument date 2018-12-10 · Revision B

Technical data

Typical properties and test methods

Request the current document for any missing data. Use only data for this product code.

Typical data from the reference TDS

CV2-2946 Product Profile / TDS · Document date 2018-12-10 · Revision B

Values are shown in the document's original units. They are Typical data, not purchasing specifications. Values from different methods or conditions are not directly equivalent.

PropertyTypical valueTest method
AppearanceWhiteASTM D2090
Work Time3 hoursNot stated in this document
Durometer, Type A55ASTM D2240
Tensile Strength400 psi / 2.75 MPaASTM D412
Elongation225%ASTM D412
Tear Strength55 ppi / 9.7 kN/mASTM D624
Collected Volatile Condensable Material (CVCM)0.01%ASTM E595

Documents & lot records

Technical and lot documents

Request the current product documents and any lot-specific records required for your project.

  • Product Profile / TDS referenceThe date identifies the reference used on this page; it does not establish the current revision, supply or a regulatory conclusion.CV2-2946 Product Profile / TDS · Document date 2018-12-10 · Revision B
  • Lot documentsRequest a CoA or other lot documents for your product code and lot.Available records depend on the product and lot

Request documents for this code

Using product information

Selection and validation

  • Typical data supports technical discussion; it is not a purchasing specification.
  • Material-level information is not finished-device approval. Suitability depends on the exact code, contact conditions and final device validation.
  • Lot documents apply to a specific production lot. Confirm current documents before design or acceptance.
  • NuSil™ and Avantor® are trademarks of their respective owners. BIO is not the manufacturer.

Discuss your application

Submit CV2-2946 and application details

Tell BIO about the component, contact conditions, process, expected volume and documents you need. Request application support, samples or a quotation.