Materials & Products
EPM-2421
Product identification
Product identification
Use the complete product code when requesting documents, samples or a quotation.
- Full product code
EPM-2421- Matching reference
- EPM-2421 Product Profile / TDSDocument date 2013-02-13
Technical data
Typical properties and test methods
For omitted items, use the product document confirmed at request time; do not fill gaps from a similar code.
Typical data from the reference TDS
EPM-2421 Product Profile / TDS · Document date 2013-02-13
Values are shown in the document's original units. They are Typical data, not purchasing specifications. Values from different methods or conditions are not directly equivalent.
| Property | Typical value | Test method |
|---|---|---|
| Appearance | Transparent | ASTM D2090 |
| Viscosity, Part A | 3,750 cP (3,750 mPas) | ASTM D1084, D2196 |
| Viscosity, Part B | 2,700 cP (2,700 mPas) | ASTM D1084, D2196 |
| Work Time | 3 hours | Not stated in this document |
| Tack-Free Time | 5 hours | ASTM C679 |
| Specific Gravity | 1.02 | ASTM D792 |
| Durometer, Type A | 50 | ASTM D2240 |
| Tensile Strength | 850 psi (5.9 MPa) | ASTM D412 |
| Elongation | 90% | ASTM D412 |
| Lap Shear Strength | 250 psi (1.73 MPa) | ASTM D1002 |
| Volatile Content (1 hour at 275°C) | 0.7% | ASTM D2288 |
| Dielectric Strength | 610 V/mil (24.0 kV/mm) | ASTM D149 |
| Dielectric Constant, 1 kHz | 2.8 | ASTM D150, D924 |
| Loss Tangent, 100 Hz | 0.0003 | ASTM D150, D924 |
| Loss Tangent, 1 kHz | 0.0004 | Not stated in this document |
Documents & lot records
Technical and lot documents
Request the current product documents and any lot-specific records required for your project.
- Product Profile / TDS referenceThe date identifies the reference used on this page; it does not establish the current revision, supply or a regulatory conclusion.EPM-2421 Product Profile / TDS · Document date 2013-02-13
- Lot documentsIf the project requires a CoA or another lot document, state it in the inquiry. Availability is confirmed for the code and actual lot.Available records depend on the product and lot
Using product information
Selection and validation
- Typical data supports technical discussion; it is not a purchasing specification.
- Material-level information is not finished-device approval. Suitability depends on the exact code, contact conditions and final device validation.
- Lot documents apply to a specific production lot. Confirm current documents before design or acceptance.
Discuss your application
Submit EPM-2421 and application details
Tell BIO about the component, contact conditions, process, expected volume and documents you need. Request application support, samples or a quotation.