Materials & Products
R-2180
NuSil™ medical-grade silicone · supplied in China by BIO, an authorized NuSil™ Channel Partner
Product identification
Product identification
Use the complete product code when requesting documents, samples or a quotation.
- Full product code
R-2180- Matching reference
- R-2180 Product Profile / TDSDocument date 2018-12-31 · Revision C
Technical data
Typical properties and test methods
Request the current document for any missing data. Use only data for this product code.
Typical data from the reference TDS
R-2180 Product Profile / TDS · Document date 2018-12-31 · Revision C
Values are shown in the document's original units. They are Typical data, not purchasing specifications. Values from different methods or conditions are not directly equivalent.
| Property | Typical value | Test method |
|---|---|---|
| Appearance | Transparent to translucent. | ASTM D2090 |
| Viscosity | 3,075 cP / 3,075 mPas | ASTM D1084, D2196 |
| Non-Volatile Content | 20% | ASTM D2288 |
| Work Time | >72 hours | Not stated in this document |
| Refractive Index | 1.41 | D1747, D1218 |
| Durometer, Type A | 40 | D2240 |
| Tensile Strength | 1,700 psi / 11.7 MPa | D412 |
| Elongation | 1,050% | D412 |
| Tear Strength | 300 ppi / 52.9 kN/m | D624 |
| Stress at 100% Strain | 150 psi / 1.03 MPa | D412 |
Documents & lot records
Technical and lot documents
Request the current product documents and any lot-specific records required for your project.
- Product Profile / TDS referenceThe date identifies the reference used on this page; it does not establish the current revision, supply or a regulatory conclusion.R-2180 Product Profile / TDS · Document date 2018-12-31 · Revision C
- Lot documentsRequest a CoA or other lot documents for your product code and lot.Available records depend on the product and lot
Using product information
Selection and validation
- Typical data supports technical discussion; it is not a purchasing specification.
- Material-level information is not finished-device approval. Suitability depends on the exact code, contact conditions and final device validation.
- Lot documents apply to a specific production lot. Confirm current documents before design or acceptance.
- NuSil™ and Avantor® are trademarks of their respective owners. BIO is not the manufacturer.
Discuss your application
Submit R-2180 and application details
Tell BIO about the component, contact conditions, process, expected volume and documents you need. Request application support, samples or a quotation.